Description: Infinity Process Meter
| Part Number | INFP-0000-DC1 |
|---|---|
| Category | Light Analysis |
| Manufacturer | Newport |
Need to purchase this item?
The INFP-0000-DC1 by Newport is an Infinity Process Meter designed to meet the demands of rigorous process applications. Boasting six full digits and versatile scaling capabilities, this meter stands as an optimal solution. Notably, it incorporates onboard excitation functionality, enabling the powering of transmitters and sensors, a feature particularly valuable in harsh operating environments, supported by a gasketed front bezel for enhanced durability. The INFP-0000-DC1 features front panel programmability, accommodating a diverse range of input types. These include 0-20 and 4-20 mAdc current inputs, unipolar and bipolar DC voltage inputs, as well as potentiometer inputs. Compatibility extends to various process sensors encompassing potentiometers, pressure transducers, and transmitters.
Configuration of the INFP-0000-DC1 is facilitated through the intuitive interface of its five front panel buttons. Additionally, remote operation is achievable through RS-232 or RS-485 communication alternatives. Connection possibilities encompass relay outputs, analog outputs, and Binary-Coded Decimal (BCD) outputs. This meter exerts comprehensive control and alarm capabilities over systems, while also affording the ability to precisely scale and offset input signals into desired engineering units. Significantly, a two-point scaling method eliminates errors propagated from sensors during signal transmission. For applications such as destructive and pressure testing, the INFP-0000-DC1 enables the display of peak and valley levels of input signals, a crucial functionality. Supported excitation sources for sensors encompass transmitters, strain gauges, and slide-wire potentiometers. Notably adaptable, this meter allows field installation for upgrades aligned with evolving user requirements. Reconfiguration is straightforward, achieved through either the front push buttons or optional serial communications board integration.
| Current Maximum Input | 200 mA |
| Polarity | Automatic |
| Noise Rejection NMR | 60 dB, 50 or 60 Hz, + Selected Filter |
| Material | 94V-0 UL-Rated Polycarbonate |
| AC Power Units | 115/230 Vac ±10%, 50/60 Hz; 12 W Max Power Consumption |
| Operating Temperature Range | 0 to 50 ºC (32 to 140°F) |
| Dimensions (H x W x D) | 1.89 in x 3.78 in x 5.86 in (48 mm x 96 mm x 145 mm) |
| Weight | 1.316 lbs (600 g) |